Analysis of Multi Source Single Load System Considering Cable Resistance in Droop Controlled DC Microgrid (Record no. 14704)

MARC details
000 -LEADER
fixed length control field 02200nam a22001817a 4500
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 621.31
Item number C496A
100 ## - MAIN ENTRY--AUTHOR NAME
Personal name Chauhan, Arimardan Singh
245 ## - TITLE STATEMENT
Title Analysis of Multi Source Single Load System Considering Cable Resistance in Droop Controlled DC Microgrid
Statement of responsibility, etc by Arimardan SinghChauhan
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication IIT Jodhpur
Name of publisher Department of Electrical Engineering
Year of publication 2018
300 ## - PHYSICAL DESCRIPTION
Number of Pages xi,36p.
Other physical details HB
520 ## - SUMMARY, ETC.
Summary, etc Coordination of different distributed generation (DG) unitsis essential to meet the increasing de-mand for electricity. Many control strategies, such as droop control, master-slave control, andaverage current-sharing control, have been extensively implemented to operate parallel-connectedconverters for load sharing in DG network. Among these methods, the droop control technique hasbeen widely accepted in the scientific community because of no dependance on critical communi-cation links among parallel-connected converters to coordinate the DG units within a microgrid.Several methods of droop control do not consider cable impedance. However, In real case, theload sharing performance with droop control gets affected by cable resistance. Selection of droopresistance value play very important role in reducing the sharing unbalances from ideal value.Chosen droop resistance value should be such that the designer is able to keep the error withinrequired limits. For this a relation between droop resistance and cable resistance has been derivedin this work by considering a worst case. Although there are various kind of configuration availableto design dc system, however for assuring the consumer at load side a simple approach is proposed.The analysis of proposed approach reflects that even in worstcase the error will be in requiredlimits. The analysis of multi source single load is presented here that helps the design engineerto choose proper droop resistance value so that the sharing unbalance error and effects from cableresistance are minimized<br/>
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical Term Single Load System
Topical Term Cable Resistance
Topical Term MTech Theses
Topical Term Department of Electrical Engineering