Analysis of Multi Source Single Load System Considering Cable Resistance in Droop Controlled DC Microgrid (Record no. 14704)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02200nam a22001817a 4500 |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 621.31 |
Item number | C496A |
100 ## - MAIN ENTRY--AUTHOR NAME | |
Personal name | Chauhan, Arimardan Singh |
245 ## - TITLE STATEMENT | |
Title | Analysis of Multi Source Single Load System Considering Cable Resistance in Droop Controlled DC Microgrid |
Statement of responsibility, etc | by Arimardan SinghChauhan |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Place of publication | IIT Jodhpur |
Name of publisher | Department of Electrical Engineering |
Year of publication | 2018 |
300 ## - PHYSICAL DESCRIPTION | |
Number of Pages | xi,36p. |
Other physical details | HB |
520 ## - SUMMARY, ETC. | |
Summary, etc | Coordination of different distributed generation (DG) unitsis essential to meet the increasing de-mand for electricity. Many control strategies, such as droop control, master-slave control, andaverage current-sharing control, have been extensively implemented to operate parallel-connectedconverters for load sharing in DG network. Among these methods, the droop control technique hasbeen widely accepted in the scientific community because of no dependance on critical communi-cation links among parallel-connected converters to coordinate the DG units within a microgrid.Several methods of droop control do not consider cable impedance. However, In real case, theload sharing performance with droop control gets affected by cable resistance. Selection of droopresistance value play very important role in reducing the sharing unbalances from ideal value.Chosen droop resistance value should be such that the designer is able to keep the error withinrequired limits. For this a relation between droop resistance and cable resistance has been derivedin this work by considering a worst case. Although there are various kind of configuration availableto design dc system, however for assuring the consumer at load side a simple approach is proposed.The analysis of proposed approach reflects that even in worstcase the error will be in requiredlimits. The analysis of multi source single load is presented here that helps the design engineerto choose proper droop resistance value so that the sharing unbalance error and effects from cableresistance are minimized<br/> |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical Term | Single Load System |
Topical Term | Cable Resistance |
Topical Term | MTech Theses |
Topical Term | Department of Electrical Engineering |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Fulwani, Deepak |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | Thesis |
Withdrawn status | Lost status | Damaged status | Not for loan | Collection code | Permanent Location | Current Location | Shelving location | Date acquired | Full call number | Accession Number | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Not For Loan | Reference | S. R. Ranganathan Learning Hub | S. R. Ranganathan Learning Hub | Course Reserve | 2024-01-24 | 621.31 C496A | TM00124 | 2024-01-24 | Thesis |